Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Pharm Sci ; 193: 106682, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38142950

RESUMO

The biopharmaceutical industry faces the challenge of efficiently characterising impurity profiles of therapeutical peptides, also due to their complex polar and ionisable attributes. This research explores the potential of advanced chromatographic techniques to address this challenge. The study compares dynamic electrostatic repulsion reversed phase (d-ERRP) to its counterparts (static ERRP and ion pair reversed phase IP-RP) in analysing Icatibant and its elusive epimeric impurity, [L-Arg]1-Icatibant and highlights its exceptional capabilities in generating symmetric peaks, mitigating the common tailing phenomenon, and serving as a steadfast guardian of column longevity. The result highlights d-ERRP as a pioneering tool in the domain of liquid chromatography, fostering its role as a reference technique for the analysis of therapeutic peptides.


Assuntos
Bradicinina , Peptídeos , Cromatografia Líquida de Alta Pressão/métodos , Peptídeos/química , Cromatografia Líquida
2.
Molecules ; 26(14)2021 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-34299626

RESUMO

Bioactive peptides are increasingly used in clinical practice. Reversed-phase chromatography using formic or trifluoroacetic acid in the mobile phase is the most widely used technique for their analytical control. However, sometimes it does not prove sufficient to solve challenging chromatographic problems. In the search for alternative elution modes, the dynamic electrostatic repulsion reversed-phase was evaluated to separate eight probe peptides characterised by different molecular weights and isoelectric points. This technique, which involves TBAHSO4 in the mobile phase, provided the lowest asymmetry and peak width at half height values and the highest in peak capacity (about 200 for a gradient of 30 min) and resolution concerning the classic reversed-phase. All analyses were performed using cutting-edge columns developed for peptide separation, and the comparison of the chromatograms obtained shows how the dynamic electrostatic repulsion reversed-phase is an attractive alternative to the classic reversed-phase.


Assuntos
Cromatografia de Fase Reversa , Peptídeos/isolamento & purificação , Peptídeos/química , Eletricidade Estática
3.
J Pharm Biomed Anal ; 191: 113584, 2020 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-32889349

RESUMO

Ampicillin, discovered in 1958, was the first broad spectrum semisynthetic penicillin introduced into the market. Despite its wide use not all the impurities have been identified to date. Herein, the last unknown impurity present in commercially available medicines was isolated and identified. This impurity that accounts up to 0.8 in area % by HPLC (EP 10.0) in the Reference Listed Drugs (RLD) was characterized and identified to be the 16-keto penicillin G. The structure was confirmed by comparison with a chemically synthesized sample. The determination of the Relative Response Factor (RRF) of the impurity respect to the parent drug allowed to recalculate the real amount that is consistently below the reporting threshold.


Assuntos
Ampicilina , Contaminação de Medicamentos , Cromatografia Líquida de Alta Pressão , Penicilinas
4.
RSC Adv ; 10(21): 12604-12610, 2020 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35497586

RESUMO

The application of a novel chromatographic approach to therapeutic peptides bearing basic amino acids in their structure allowed unprecedented resolution of their related impurities (including epimeric isobaric ones), resulting in a superior analytical tool for the evaluation of the quality of these drugs in the market.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...